Seitenansicht 2
Film capacitors – Power Factor Correction B44066R7415E230
Key components – PF controller BR7000
Preliminary data
FK PC PM PFC March 2009
Please read Cautions and warnings and Page 3 of 7
Important notes at the end of this document.
Controlling
Simple controlling 3-phase (3-phase capacitors), max. 15 switching outputs. For 3-phase-
measurement: controlling is done either according to the worst cos φ or average value. For single-
phase-measurement: 2 current inputs are additionally available for measured capacitor bank
currents
Single phase controlling: max. 5 switching outputs for each phase (3 · 5 switching outputs); each
phase is controlled separately. Single phase capacitors are switched to neutral.
Mixed controlling: e.g. 3 · 3 single phase capacitors per phase (L-N) for balancing and additional 6
outputs for normal 3-phase-capacitors.
Separate controlling of single phase capacitors L-L (without neutral)
Error messages
Over voltage/under voltage/no voltage
Over current
Over/under compensated
Harmonics (THD exceeded)
Over temperature
C-defect
Warning switching operations
Internal alert message with time stamp
1 alarm relay
1 relay freely programmable
1 relay for fan control
Inputs
Operating voltage input: 110 … 230 V AC ±15 %
3 measuring voltage inputs: 30 … 440 V AC (L-N) / 690 V AC (L-L)
3 current inputs: X:1A / X:5A
1 external input
Outputs
3 · 5 relay outputs (contact NO) as switching outputs
3 relay outputs (contact NO) for message/alarm/fan
2 independent isolated interfaces RS485